產(chǎn)品分類 更多>>

加工定制
品牌
SEIKA
型號(hào)
NA2-10
種類
角度
制作工藝
集成
輸出信號(hào)
模擬型
防護(hù)等級(jí)
IP65
線性度
0.03degrees(%F.S.)
靈敏度
200 mV/degree
漂移
0.002degrees/Kelvin
分辨率
0.002degree





Features

  • small size light weight
  • linear output response
  • high measurement accuracy
  • small zero drift
  • small cross sensitivity
  • high long term stability - virtually infinite lifespan
  • hysteresis-free output signal
  • integrated sensor electronics including signal conditioner and low-pass filter
  • no data memory with memory loss
  • temperature compensated, conditioned 0...5V output signal
  • highly stable internal voltage regulation
  • optional 5 Volt reference voltage output
  • unconditioned operating voltage between 9V and 30V
  • low power consumption
  • protection against reverse supply voltage polarity
  • EMC certified CE certified
  • no interference by surrounding electromagnetic fields
  • shockproof as without moving mechanical parts
  • hermetically sealed
  • sensor electrically isolated from point of measurement by high quality plastic housing – no ground connection
  • zero point adjustable through 360° using clamping ring

Description

The capacitive, dielectric liquid based inclinometers NA2-05, NA2-10, NA3-30, NA4-45 and NA4-70 contain new sensor electronics. These are made up of a highly stable, laser-trimmed signal conditioner with electronic compensation for temperature drift, highly stable supply voltage regulation circuitry and low-pass filtering of the measurement signal to eliminate unwanted noise.

The capacitive measurement principle guarantees a very stable, linear relationship between the inclination being measured and the normalised output signal.

The sensor electronics require minimal power and, together with the capacitive primary transformer, are characterised by low errors, high signal-to-noise ratio and high long-term stability.

Contrary to measuring inclinations using accelerometers, this measurement principle enables a linear relationship between the inclination to be measured and the output signal, independent of the constant of gravity at the place of measurement, i.e. Independently of where the measurement is taking place, whether in Europe, Australia, on Mount Everest or the Moon.

Application

The NA2, NA3 and NA4 can be used for measurements requiring small and light devices, replacability, measurement of relatively large inclinations and a normalised, analogue voltage output signal.

Measurements of inclinations in measuring instruments and inspection equipment, in water, land and air vehicles, in automation and safety technology, on cranes and lifting equipment, on robots, in the manufacture of scientific equipment, in medicine and telecommunication as well as navigation systems are typical examples.

Shared Technical Specifications

Supply voltage 1)9V … 30V DCDimensionssee dimension drawing
Current drawnca. 2mAReference voltage output 3)5,00 Volt
Externally regulated supply voltage 2)5 VoltTemperature drift of the reference voltage< 25 ppm/K
Current drawn with external supply voltage 5Vapprox. 1mAMaximum current of the reference voltage output5mA
Maximum Operating Temperature+85°COutput resistanceca. 100 Ohm
Minimum Operating Temperature-40°CProtectionIP 65
Maximum Storage Temperature+90°CWeight (Sensor excluding mounting ring and cable)18,5 g
Minimum Storage Temperature-55°CEnviroment Humiditi0…100% r.F.
Signal-to-noise ratio at signal output (0…10kHz)<150µVssElectrical signal-to-noise ratio>85dB
Transverse sensitivity
at 45° tilt
<1% of measure-ment valueVoltage Offset (at Cero degree tilt)2,5 Volt
Settling time (to 98% of the actual value)<0,3 sMaximum output voltage range0.05V ... 4.95V
Terminals3 (4) highly flexible cables, Øca.1mm, length 18cm
optionally: shielded cable Ø2,1mm

Notes:

1) Standard supply voltage

2) optional externally regulated supply voltage

3) reference voltage output (+5,00 V) only optionally connected (for wire terminals only)

Each sensor will be delivered with individual calibration dates (offset, sensitivity) and calibration record.

Technical Specifications of types NA2-05 and NA2-10

Typ NA2-05 NA2-10
Measuring range±5degrees±10degrees
Resolution<0,001degrees <0,002degrees
Nominal sensitivity400mV/degree200mV/degree
Output voltage range2,5V±2V at ±5°2,5V±2V at ±10°
Linearity deviation over whole measurement range<±0,02degrees<±0,03degrees
sensitivity shift over a temperature range -25°C...85°C<2%<2%
Temperature drift of zero point±0,002degrees/Kelvin±0,002degrees/Kelvin

Technical Specifications of types NA3-30, NA4-45 and NA4-70

Typ NA3-30 NA4-45 NA4-70
Measuring range±30degrees±45degrees ±70degrees
Resolution<0,005degrees<0,01degrees <0,01degrees
Nominal sensitivity66,6.. mV/degree44,4.. mV/degree28,57 mV/degree
Output voltage range2,5V±2V at ±30°2,5V±2V at ±45°2,5V±2V at ±70°
Linearity deviation over whole measurement range< 0,06 degrees< 0,14 degrees< 0,28 degrees
sensitivity shift over a temperature range -25°C...85°C<2%<2%<2%
Temperature drift of zero point±0,002deg/Kelvin±0,003deg/Kelvin±0,003deg/Kelvin

Summary of standard SEIKA products

Static Accelerometers (lower cut-off frequency = 0 Hz)

Model Measuring rangeResolution
B1, B2, B3±3g, ±10g, ±50g ( 1g = 9.81ms-2 )<0.001g, <0.005g, <0.01g

Dynamic Accelerometers (lower cut-off frequency = 1 or 10 Hz)

ModelMeasuring rangeResolutionFrequenzy range
BDK3± 3 g < 10-3 g 1...300 Hz
BDK10± 10 g < 5*10-3 g 1... 800 Hz
BDK100± 100 g < 1*10-2 g 1... 1.5 kHz

Inclinometers

ModelMeasuring rangeResolution
NB3±10° (±20°) <0.001°
NA2-05, NA2-10

NA3-30

NA4-45, NA4-70

±5°, ±10°

±30°

±45°, ±70°

<0.001Grad, <0.002Grad

<0.005Grad

<0.01Grad, <0.01Grad

N2, N3, N4±10°, ±30°, ±70° <0.001°, <0.005°, <0.005°
NG2, NG3, NG4±10°, ±30°, ±80° <0.001°, <0.005°, <0.005°
NG...IInclinometer type NG2, NG3, NG4 with integrated 4...20mA signal conditioner
NG...U Inclinometer type NG2, NG3, NG4 with integrated 0...5V signal conditioner
NG360 Inclinometer with 360° measuring range and integrated microprocessor and RS485 interface

Sensor boxes (for harsh operating conditions)

Model Features
SB1ISensor box (98 x 64 x 56mm3) with one integrated SEIKA sensor of any type and one integrated signal conditioner with 4...20mA output.
SB2ISensor box (98 x 64 x 56mm3) with two integrated SEIKA sensors of type B, BD, BDK, N or NB and two integrated signal conditioners with a 4...20mA output each. Both channels are electrically isolated from each other.
SB1USensor box (98 x 64 x 56mm3) with one integrated SEIKA sensor of any type and one integrated signal conditioner with 0...5V output.
SB1SSensor box (98 x 64 x 56mm3) with one integrated SEIKA sensor of any type, one integrated signal conditioner with 0...5V output and two open collector switch outputs that respond to traversing of adjustable thresholds.
SBS1USensor box (98 x 64 x 56mm3) with one integrated SEIKA-Servo-Inclinometer for measuring small angles of up to 2 degrees with very high resolution and an integrated signal conditioner with 0...5V output.
SB360Sensor box (98 x 64 x 56mm3) with one integrated SEIKA sensor of type NG360, internal microprocessor and RS485 interface.
SBG2USensor box (124 x 80 x 58mm3) with two integrated SEIKA sensors of type NG and two 0...5V outputs.
SBG3ISensor box (124 x 80 x 58mm3) with three integrated SEIKA sensors and three integrated signal conditioners with 4...20mA output.
SBL1Sensor box (180 x 180 x 100mm3 - large and robust) with one integrated SEIKA sensor of any type and one integrated signal conditioner with 4...20mA output.
SBL1SSensor box (180 x 180 x 100mm3 - large and robust) with two integrated SEIKA sensors of any type, one integrated signal conditioner with 4...20mA output, one integrated signal conditioner with 0...5V output and two safety relays that respond to traversing of adjustable thresholds. The SBL1S has two redundant, electrically isolated measuring channels for safety related applications.
XB..Extra robust, pressure-, saltwater- and corrosion-proof stainless steel sensor box (ø120 x 50) as an alternative to the SB.. housings (180 x 180 x 100mm3) for especially harsh operating conditions, aggressive fluids and saltwater.
SC485BBox (63.5 x 58 x 35mm3) with RS485/RS232 converter for operation of inclinometers NG360, SB360, and XB360 from a RS232 port.

Sensor accessories

ModelFeatures
NV4aFiltering signal conditioner for sensor signal matching with symmetrical +/- 4 V voltage output
NV6aFiltering signal conditioner for sensor signal matching to a 4...20mA, 2-wire interface
NV8aFiltering signal conditioner for sensor signal matching with an asymmetric 0...5V output voltage
SW3Sensor cube for multiaxial arrangement of SEIKA accelerometers and/or SEIKA inclinometers
SBBS, SBBB, SBBWFixing plates from stainless steel for sensor boxes SB..
產(chǎn)品推薦
“供應(yīng) 德國(guó)賽卡SEIKA NA2-10 傾角計(jì) 傾斜儀 角度計(jì) 角度傳感器”信息由發(fā)布人自行提供,其真實(shí)性、合法性由發(fā)布人負(fù)責(zé)。交易匯款需謹(jǐn)慎,請(qǐng)注意調(diào)查核實(shí)。